OS GSO IEC 60317-33:2014
IEC 60317-33:1990
Omani Standard
Current Edition
·
Approved on
25 December 2014
Amendment 2 - Specifications for particular types of winding wires - Part 33: Glass-fibre wound resin or varnish impregnated, bare or enamelled rectangular copper wire, temperature index 200
OS GSO IEC 60317-33:2014 Files
English
15 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
OS GSO IEC 60317-33:2014 Scope
This International Standard specifies requirements of glass-fibre wound impregnated, bare grade 1
or grade 2 enamelled rectangular copper winding wire, temperature index 200. The impregnating
agent can be, for instance, polyesterimide or silicon resin based.
NOTE - For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be
established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot
be specified.
The enamelled wire shall be based on one of the following standards and shall be agreed between
purchaser and supplier.
IEC 60317-28:1990, Specifications for particular types of winding wires – Part 28: Polyesterimide
enamelled rectangular copper wire, class 180
IEC 60317-29:1990, Specifications for particular types of winding wires – Part 29: Polyester or
polyesterimide overcoated with polyamide-imide enamelled rectangular copper wire, class 200
IEC 60317-30:1990, Specifications for particular types of winding wires – Part 30: Polyimide
enamelled rectangular copper wire, class 220
When an enamelled wire is used, it must have a minimum class of 180.
The temperature index of the glass-fibre wound impregnated wire is dependent upon the type of
impregnating agent used. The impregnating agent applied to the glass fibre should have a
minimum temperature index of 200.
The glass-fibre covering may be:
a) a single layer of glass-fibre;
b) double layer of glass-fibre, with one layer applied in the direction opposite to that of the other
layer.
The range of nominal conductor dimensions covered by this standard is:
– width: min. 2,0 mm max. 16,0 mm;
– thickness: min. 0,80 mm max. 5,60 mm.
The specified combinations of width and thickness as well as the specified width/thickness ratio
are given in IEC 60317-0-4.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 2530:2016
GSO 2530:2016
Omani Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 34:2007
GSO 34:2007
Omani Standard
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
Recently Published from Electrical Sector
GSO IEC 61643-41:2026
IEC 61643-41:2025
Gulf Standard
Low-voltage surge protective devices - Part 41: Surge protective devices connected to DC low-voltage power systems – Requirements and test methods
GSO IEC 60704-2-3:2026
IEC 60704-2-3:2025
Gulf Standard
Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 2-3: Particular requirements for dishwashers
GSO IEC 60270:2026
IEC 60270:2025
Gulf Standard
High-voltage test techniques – Charge-based measurement of partial discharges
GSO IEC PAS 63629:2026
IEC PAS 63629:2025
Gulf Standard